Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chongqing Medicine ; (36): 3088-3089, 2017.
Article in Chinese | WPRIM | ID: wpr-608811

ABSTRACT

Objective To explore the diagnostic and clinical application value of combined detection of C-reactive protein (CRP),serum prealbumin (PA) and white blood cell (WBC) count in neonatal infectious diseases.Methods A total of 187 fullterm newborns were collected in this study,including 92 newborns of bacterial infection as the infection group and 95 newborns of non-infection diseases as non-infection group.The abnormal rates of CRP,PA and WBC in the two groups were measured;the sensitivity,specificity,false positive rate and false negative rate were compared between the single detection and combined detection of WBC,PA,CRP;the changes of the three indexes in the infection group were compared between before and after treatment.Results The abnormal rates of CRP,PA and WBC in the infection group were significantly higher than those in the non-bacterial infection diseases group (P<0.05).The sensitivity and specificity of combined detection of CRP+ PA + WBC were higher than those of single detection of CRP,PA and WBC;after treatment,the level of CRP in the infection group was significantly decreased,the level of PA was significantly increased and the WBC count returned to normal(P<0.05).Conclusion The combined detection of CRP,PA and WBC has an important clinical value in the early diagnosis of neonatal bacterial infection.

2.
Academic Journal of Second Military Medical University ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-552242

ABSTRACT

Objective: To analyze the design of Nitinol Patellar Concentrator (NT-PC) and its biomechanic characteristics for treating comminuted patellar fractures.Methods:NT-PC and patellar was analyzed by ANSYS software,the finite element was three dimension brick unit with 20 nodes, 8 faces, and the degree of freedom was 6.In NT-PC,10 483 units were divided and the number of nodes was 17 959;In Patellar,8 775 units were divided and the number of nodes was 15 847.The patellar model was loaded according to the 5 converging directions of NT-PC.Results:NT-PC had tension force on its internal face and pressure force in its external face.The maximum value was 195.8 MPa and -18 MPa,which was far from its utmost stress and fatigue limit.The memory converging force of NT-PC was 134 N.The stress (0.8 MPa) was evenly distributed on the patellar surface.Stress calculation of every node indicated that positive stress was the main stress.Conclusion: The design of NT-PC is reasonable and has good reusing character.After fixation, exercise is allowed immediately after operation.The continual positive stress is good for the stability of fracture end and fracture healing.

3.
Academic Journal of Second Military Medical University ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-677551

ABSTRACT

Objective:To study the biomechanical basis of swan like memory compressive connector (SMC) for treating fractures and nonunions, and the facilitating effects of dynamic memorial stress of SMC for bone healing. Methods:By computer emulation and three dimensional (3D) finite element analysis, the biomechanical behavior of humeral type connector for fixing humerus was emulated and analyzed. The finite element model of humeral type connector was divided into 3 487 units. The number of nodes was 5 397. The element was a unit with 20 nodes, 4 faces. The finite element model of humerus was divided into 5 783 units, the number of nodes was 9 863. And the finite element was a 3D unit with 10 nodes, 4 faces.Results:When the connector fixated humerus, it came in for tension stress in its inner surface, and compressing stress in its outer surface. The maximum first structural major stress of metamorphosed compressive part was 224.5 MPa and -34 MPa, far less than its utmost stress and fatigue limit. The initiative memorial bone holding force for maintaining axial stability was 125.05 N, and the longitudinal initiative memorial compression force was 196 N. The stress distribution in fixed humerus was even, the stress in most nodes was positive stress. Conclusion:The SMC has good anti fatigue and reuse characters. The dynamic memorial compressive stress field is good for the stability of fixation and enhancement of bone healing.

SELECTION OF CITATIONS
SEARCH DETAIL